中文
Folded with valve mask
[Model]:FLY-ZD-P3
[Class]: FFP3 NR
[Packing Specifications]:15PCS/box
[Size] 16cm * 10.8cm
[Compliant to EN Standards]: EN 149:2001+A1:2009

DETAIL

  • 【Structure and composition】 This product is filtering half mask without valve to protect against particles, limited to one shift use only. The product is composed of mask body, nose clip and ear straps and adjusters. The mask body has a five-layer structure. Both the inner and outer layers are made of non-woven fabric. The intermediate filter layer is 2 layers melt-blown PP and hot air cotton. The nose clip is made of iron and PP. The ear strap is made of polyester. The adjuster is made of PP.The white polyurethane sponge strip is also provided.
  • 【Indications For Use】The protective mask is intended used for protection against solid and oily particulates, liquid and microorganisms such as coal dust, cement dust, acid fog, paint fog, oil smoke, oil mist, asphalt smoke, coke oven smoke etc. Single-use.
  • 【Limitations】Not suitable for working places where open flames exist (such as welding,casting,etc,); It is not suitable for professional protective use such as oxygen deficient, toxic gas environment. No medical use.
  • 【Checks prior to use】Before use, check whether the package of the mask is damaged and the components are intact. In case of any stain or damage, discontinue use immediately.
  • 【Transporting】When transporting this product use original packaging provided.
  • 【USE CAUTIONS】 a)Please check fit of mask prior to use;
    b)It is unlikely that the requirements for leakage will be achieved if facial hair passes under the face seal;
    c)Please do not use the mask under low air quality condition, such as serious contaminants in air, oxygen deficiency
    d)Do not use the mask in explosive atmosphere;
    e)After use, please discard the mask following local regulation;
    f)The mask is only for single use, do not use repeatedly.
    g) “Warning - this product is not flame resistant and must not be used in areas with open flames”
    h) Discard the respirator and replace with a new one if excessive clogging of the particle filtering half mask cause breathing difficulty or the particle filtering half mask becomes damaged.
    i) Do not use the same respirator for more than 8 hours continuous or intermittent, in dirty workplaces that could result in high filter loading.

    See information supplied by the manufacturer.

Fitting

  • 1. Open the mask to make the nose clip at the top, and pull the ear straps with both your hands.
    2. Hold the mask against your chin to completely cover your nose and mouth.
    3. Pull the ear straps behind your ears and adjust them to make you feel comfortable.
    4. Use both your hands to adjust the shape of the nose clip. Place your fingers in the middle of the nose clip and press it inwards while moving your fingertips along both sides of the nose clip until it is pressed to fit the bridge of your nose. (Making the nose clip, get a seal with only one hand may affect the tightness of the mask). Adjust the adjuster so to fix the mask, and make the people more comfortable.
    5. Cover the mask with your hand and exhale vigorously. If you feel the air escaping from the nose clip, it is required to tighten the nose clip, if the air escapes from the edge of the mask, readjust the headband to ensure tightness.
    Please carefully follow these fitting instructions during each use to achieve proper fit.
    Storage Condition: : The product should be stored in a well ventilated, dark and dry environment. Keep away from fire, pollutants and possible pollution sources. Also, the transport storage ‘s temperature: -5℃~50℃, relative humidity: < 75%RH.
    CompleteShelf-Life: The Protective Mask is valid for 3 years with the above storage condition.
    Production Batch Number: Printed on the bottom
    Production Date: Printer on the bottom
    Expiration Date: Printer on the bottom
    Manufacturer: Guangdong Fengluyuan Biopharmaceutical Technology CO., LTD
    Complete Address: Building 2nd, Guantai Biotechnology Cooperation And Breeding Center 1# Taoyuan Road, Taiwan Hi-tech Park, Songshan Lake, Dongguan Guangdong China.
    Phone: 0769—22426953
    Company Website:www.fenglvyuan.com
    Notified Body for EU type-examination and production control:
    Notified Body Name : LGAI TECHNOLOGICAL CENTER, S.A. (APPLUS)
    Notified Body Address : Campus de la UAB - Ronda de la Font del Carme s/n08193Bellaterra (Barcelona)
    Notified Body No. : 0370

Cert & report

EU CE CERTIFICATE FOR FOLD FFP3 PROTECTIVE MASK

TEST REPORT OF FOLD FFP3 PROTECTIVE MASK

English
折叠带阀面罩
[型号]:FLY-ZD-P3
[类别]:FFP3 NR
[包装规格]:15片/盒
[尺寸] 16cm * 10.8cm
[符合EN标准]:EN 149:2001 + A1:2009

详情

  • 【结构组成】 本产品是过滤半面罩,不带阀门以防止颗粒,仅限一班使用。 该产品由面罩主体,鼻夹,耳带和调节器组成。面罩主体具有五层结构。内层和外层均由无纺布制成。中间过滤层为两层熔喷PP和热风棉。鼻夹由铁和PP制成。耳带由聚酯制成。 调节器由PP制成,还提供白色聚氨酯海绵条。
  • 【使用指征】 防护面罩用于防止固体和油性微粒,液体和微生物,例如煤尘,水泥尘,酸雾,油漆雾,油烟,油雾,沥青烟,焦炉烟等。一次性使用。
  • 【限制条件】 不适合存在明火的工作场所(例如焊接,铸造等);它不适用于氧气不足,有毒气体环境等专业防护用途。 无医疗用途。
  • 【使用前检查】 使用前,请检查口罩包装是否损坏以及部件是否完好。 如有任何污渍或损坏,请立即停止使用。
  • 【运输方式】 运输本产品时,请使用提供的原始包装。
  • 【使用注意事项】 a)使用前请检查口罩是否合适;
    b)如果面部毛发经过面部密封处,则不可能达到泄漏要求;
    c)请不要在空气质量低的环境下使用口罩,例如空气中的严重污染物,氧气不足
    d)请勿使用口罩在易爆环境中;
    e)使用后,请按照当地规定丢弃口罩;
    f)口罩仅供一次性使用,请勿重复使用。
    g)“警告-此产品不阻燃,切勿在明火的地方使用”
    h)如果颗粒物过滤半面罩的过多堵塞导致呼吸困难或颗粒物过滤半部被堵塞,则丢弃呼吸器并更换新的呼吸器。面罩受损。
    i)在肮脏的工作场所中,连续或间歇使用同一呼吸器的时间不得超过8小时,否则可能会导致过滤器负荷过高。

    请参阅制造商提供的信息。

配件

  • 1.打开面罩,使鼻夹在顶部,然后用双手拉动耳带。
    2.将面罩靠在下巴上,完全遮住鼻子和嘴巴。
    3.将耳带拉到耳朵后面,并进行调节以使您感到舒适。
    4.双手调整鼻夹的形状。 将手指放在鼻夹的中间,然后向内按下,同时沿鼻夹的两侧移动指尖,直到将其按入以适合鼻梁为止。(制作鼻夹,仅用一只手密封即可影响面罩的松紧度)。 调整调节器,以固定口罩,并使人们更舒适。
    5.用手遮住口罩并用力呼气。 如果感觉到鼻夹有空气逸出,则需要拧紧鼻夹,如果空气从面罩边缘逸出,请重新调整头带以确保牢固。
    每次使用时,请仔细遵循这些安装说明,以实现正确的安装。
    储存条件:该产品应储存在通风良好,黑暗干燥的环境中。 远离火源,污染物和可能的污染源。 另外,运输仓库的温度:-5℃〜50℃,相对湿度:<75%RH。
    CompleteShelf-Life:在上述储存条件下,防护面膜的有效期为3年。
    生产批号:在底部打印
    生产日期:在底部打印
    到期时间:在底部打印
    制造商:广东丰绿源生物制药技术有限公司
    完整地址:中国广东省东莞市松山湖高科技园区桃园路1号莞台生物技术合作与育成中心2号楼。
    电话:0769—22426953
    公司网站:www.fenglvyuan.com
    欧盟类型检验和生产控制的
    指定机构 指定机构名称:LGAI TECHNOLOGICAL CENTRE,SA(APPLUS)
    指定机构地址:UAB校园-Ronda de la Font del Carme s / n08193Bellaterra(Barcelona)
    指定机构编号:0370

证书报告

折叠FFP3防护口罩CE认证

折叠FFP3防护口罩检测报告