中文
Cup-shaped without valve mask
[Model] FLY-BXQF-P3
[Class]: FFP3 NR
[Packing Specifications]:20PCS/box
[Size] 14.7cm * 12.6cm * 5.8cm
[Compliant to EN Standards]: EN 149:2001+A1:2009
[Trademark] FENG LV YUAN

DETAIL

  • 【Structure and composition】 This product is filtering half mask with valve to protect against particles, limited to one shift use only. The product is composed of mask body, nose clip and ear straps and adjusters. The mask body has a four-layer structure. Both the inner and outer layers are made of needle punched cotton. The intermediate filter layer is 2 layers melt-blown PP. The nose clip is made of silver aluminum alloy. The ear strap is made of polyester. The adjuster is made of PP. The valve is made of PP and silica. The inner layer of the mask also has a circle of poron made of artificial leather
  • 【Indications For Use】The protective mask is intended used for protection against solid and oily particulates, liquid and microorganisms such as coal dust, cement dust, acid fog, paint fog, oil smoke, oil mist, asphalt smoke, coke oven smoke etc. Single-use
  • 【Limitations】Not suitable for working places where open flames exist (such as welding,casting,etc,); It is not suitable for professional protective use such as oxygen deficient, toxic gas environment. No medical use.
  • 【Checks prior to use】Before use, check whether the package of the mask is damaged and the components are intact. In case of any stain or damage, discontinue use immediately.
  • 【Transporting】When transporting this product use original packaging provided.
  • 【USE CAUTIONS】 a)Please check fit of mask prior to use;
    b)It is unlikely that the requirements for leakage will be achieved if facial hair passes under the face seal;
    c)Please do not use the mask under low air quality condition, such as serious contaminants in air, oxygen deficiency
    d)Do not use the mask in explosive atmosphere;
    e)After use, please discard the mask following local regulation;
    f)The mask is only for single use, do not use repeatedly.
    g) “Warning - this product is not flame resistant and must not be used in areas with open flames”
    h) Discard the respirator and replace with a new one if excessive clogging of the particle filtering half mask cause breathing difficulty or the particle filtering half mask becomes damaged.
    i) DO not use the same respirator for more than 8 hours continuous or intermittent, in dirty workplaces that could result in high filter loading.

    See information supplied by the manufacturer.

Fitting

  • STEP 1. Hold the respirator in hand with the nosepiece at your fingertips,allowing the headbands to hang freely below your hand.
    STEP 2. Press the respirator firmly against your face with the nosepiece on the bridge of your nose.
    STEP 3. Stretch and position the top band high on the back of the head.Stretch the bottom band over the head and position below your ears.
    STEP 4. Using both hands,mold nosepiece to the shape of your nose. Adjust the adjuster so to fix he mask, and make the people more comfortable.
    STEP 5.TO test fit: a)Cuo both hands over the respirator being careful not to distrub position,and b) inhale vigorously.if air leaks around the edges, reposition the straps or adjust strap tension for better fit.
    Please carefully follow these fitting instructions during each use to achieve proper fit. Storage Condition: The product should be stored in a well ventilated, dark and dry environment. Keep away from fire, pollutants and possible pollution sources. Also, the transport storage ‘s temperature: -5℃~50℃, relative humidity: < 75%RH.
    CompleteShelf-Life: The Protective Mask is valid for 3 years with the above storage condition.
    Production Batch Number: Printed on the bottom
    Production Date: Printer on the bottom
    Expiration Date: Printer on the bottom
    Manufacturer: Guangdong Fengluyuan Biopharmaceutical Technology CO., LTD
    Complete Address: Building 2nd, Guantai Biotechnology Cooperation And Breeding Center 1# Taoyuan Road, Taiwan Hi-tech Park, Songshan Lake, Dongguan Guangdong China.
    Phone: 0769—22426953
    Company Website:www.fenglvyuan.com
    Notified Body for EU type-examination and production control:
    Notified Body Name : LGAI TECHNOLOGICAL CENTER, S.A. (APPLUS)
    Notified Body Address : Campus de la UAB - Ronda de la Font del Carme s/n08193Bellaterra (Barcelona)
    Notified Body No. : 0370

Cert & report

EU CUP FFP3 WITH VALVE PROTECTIVE MASK CE CERTIFICATE

TEST REPORT OF CUP FFP3 WITH VALVE PROTECTIVE MASK

English
杯形不带阀罩
[型号] FLY-BXQF-P3
[类别]:FFP3 NR
[包装规格]:20片/盒
[尺寸] 14.7cm * 12.6cm * 5.8cm
[符合EN标准]:EN 149:2001 + A1:2009
[商标] FENG LV YUAN

详情

  • 【结构组成】 该产品是带阀门的过滤半面罩,可防止颗粒进入,仅限一班使用。 该产品由面罩主体,鼻夹,耳带和调节器组成。面罩主体具有四层结构。内层和外层均由针刺棉制成。中间过滤层是两层熔喷PP。鼻夹由银铝合金制成。耳带由聚酯制成。调节器由PP制成。该阀由PP和硅胶制成。 面罩的内层也有一个人造皮革制成的po孔
  • 【使用指征】 防护面罩用于防止固体和油性微粒,液体和微生物,例如煤尘,水泥尘,酸雾,油漆雾,油烟,油雾,沥青烟,焦炉烟等。
  • 【限制条件】 不适合存在明火的工作场所(例如焊接,铸造等);它不适用于氧气不足,有毒气体环境等专业防护用途。 无医疗用途。
  • 【使用前检查】 使用前,请检查口罩包装是否损坏以及部件是否完好。 如有任何污渍或损坏,请立即停止使用。
  • 【运输方式】 运输本产品时,请使用提供的原始包装。
  • 【使用注意事项】 a)使用前请检查口罩是否合适;
    b)如果面部毛发经过面部密封处,则不可能达到泄漏要求;
    c)请不要在空气质量低的环境下使用口罩,例如空气中的严重污染物,氧气不足
    d)请勿使用口罩在易爆环境中;
    e)使用后,请按照当地规定丢弃口罩;
    f)口罩仅供一次性使用,请勿重复使用。
    g)“警告-此产品不阻燃,切勿在明火的地方使用”
    h)如果颗粒物过滤半面罩的过多堵塞导致呼吸困难或颗粒物过滤半部被堵塞,则丢弃呼吸器并更换新的呼吸器。面罩受损。
    i)在肮脏的工作场所中,连续或间歇使用同一呼吸器的时间不得超过8小时,否则可能会导致过滤器负荷过高。

    请参阅制造商提供的信息。

配件

  • 步骤1.用手握住呼吸器,使鼻子保持在您的指尖,使头带自由悬挂在手下方。
    步骤2.用鼻托将呼吸器紧贴在您的脸上,并将其放在鼻梁上。
    步骤3.拉伸并将顶部绑带放在头后部的高处。将底部绑带拉到头顶上,并放在耳朵下方。
    步骤4.用双手将鼻梁模制成鼻子的形状。 调整调节器,以固定口罩,并使人们更舒适。
    步骤5.要进行测试安装:a)双手握住呼吸器,注意不要扰乱其位置; b)大力吸气。如果空气泄漏到边缘,请重新调整皮带的位置或调整皮带的拉力,以使其更舒适。
    每次使用时,请仔细遵循这些安装说明,以实现正确的安装。 储存条件:产品应储存在通风良好,黑暗干燥的环境中。远离火源,污染物和可能的污染源。 另外,运输仓库的温度:-5℃〜50℃,相对湿度:<75%RH。
    CompleteShelf-Life:在上述储存条件下,防护面膜的有效期为3年。
    生产批号:在底部打印
    生产日期:在底部打印
    到期时间:在底部打印
    制造商:广东丰绿源生物制药技术有限公司
    完整地址:中国广东省东莞市松山湖台湾高科技园区桃园路1号莞台生物科技合作育成中心2号楼。
    电话:0769—22426953
    公司网站:www.fenglvyuan.com
    欧盟类型检查和生产控制的
    公告机构 公告机构名称:LGAI技术中心,SA(APPLUS)
    公告机构地址:UAB校园-Ronda de la Font del Carme s / n08193Bellaterra(巴塞罗那)
    公告机构编号:0370

证书报告

杯型FFP3带阀防护口罩CE证书

杯型FFP3带阀防护口罩检测报告